Kendal Power Station

Product: SE: Oily Water Systems
Industry: Energy: Power Station
Client: Kendal Power Station
Location: Gauteng , South Africa
Application: Treatment of oily water wastes from heavy vehicle workshop & vehicle washing. Oil is collected in an above ground tank with automatic drain back to the water collection pit. Depot Effluent Treatment.

Equipment Supplied:

  • 2 Ultraspin OS35
  • 4 Skimmers
  • 1 ES 1600 Compressor
  • S2 suction skimmer and S1 suction skimmer for primary treatment.

Typical Process Data: Treated Water Flow  Up to 3,5m 3/hr
Pump Feed Pressure: 300 to 400 kPa
Temperature: 5 to 25 ° C

Oil Type:

  • Diesel
  • Engine oil
  • Lubrication oil

Design Influent:

Oil and grease (mg/l): 90 to 2500
Suspended solids (mg/l): 1000 to 100

Design Effluent:

Oil and grease (mg/l): < 50 or <100
Suspended solids (mg/l): < 300

Start Up Date: September, 2004
Discharge Source: Storm water

System Advantages:

  • System performance easily within stormwater discharge limits
  • Low operating and maintenance cost
  • Performance improvements can be made
  • Very small footprint compared to C.P.S
  • Pressurised water and oil discharges

Back Procon Environmental Products and Technologies

Contact Procon at our Witbank or Pretoria branch now!

 

Contact us

Contact us at our Pretoria or Witbank branch in South Africa

Witbank

Telephone numbers:
+27 (0) 860 66 66 22 
+27 (0) 13 697 4617/34 
Fax numbers:
+27 (0) 13 697 4618 
procon@pro-enviro.co.za 

Pretoria

Telephone number:
+27 (0)12 674 9030

+27 (0) 860 66 66 33 
Fax number:
+27 (0) 86 680 8448 
jsteyn@pro-enviro.co.za

 

Contact Procon now for more information or prices on our products

Case Studies

There's More

Procon Brochure